+7 (812) 380-20-02   +7 911 132-78-65   gdv.kti@gmail.com

Back to descriptions of GDV devices

Technical Characteristics of GDV devices:

GDV Camera"GDV Camera"GDV Camera

GDV Camera
  1. Operating conditions:
    - air temperature from +10°C  to  +35°C;
    - relative air humidity up to 75%  at  +30°C;
    - air pressure from  84  to  106,7 kPa  (630 - 800 mm Hg).
  2. Operation - from an external power supply 12±1 V DC.
  3. Maximal power consumption - no more than  35 W.
  4. Weight with accessories - no more than 5 kg.
  5. Overall dimensions - no more than  210x390x120 mm.
  6. Pulse repetition frequency   1000±100 Hz.
  7. Single pulse duration - no more than 10 µs.
  8. Automatic exposure - 0,5 s; 1,0 s; 2 - 32 s.
  9. USB-port control of the operation and image transmission to the computer.
  10. Operation during 8 hours in an off and on operating mode: 30 min of operation should be followed by a 5 min break.
  11. Average lifetime - no less than 4 years.
| Top |

GDV Compact"GDV Compact Eco"GDV Compact

GDV Compact

1. Amplitude of generated high-voltage pulses: not more than 5 kV.
2. Pulse repetition rate 1024 Hz.
3. Single pulse duration: not more than 10 μs.
4. Operating conditions:
  – Air temperature from +10°C to +35°C;
  – Relative air humidity 75% at +30°C; 
  – Air pressure from 84 to 106.7 kPa (630–800 mm Hg).
5. The analyzer works from an external DC power supply 12±1V.
6. Maximum power consumption: not more than 20 V.
7. Mass in full package: not more than 4.5 kg.
8. Overall dimensions: not more than 250x200x130 mm.
9. The analyzer is controlled from the computer via serial USB port of from the keyboard on the face surface of the device in off-line mode.
10. Image transmission to the computer is performed via serial USB port or recorded to the USB flash drive.
11. Flash drive memory: not more than 8 Gb.
12. Average lifetime: not more than 4 years.

| Top |

GDV Compact"GDV Compact"GDV Compact

GDV Compact
  1. Operating conditions:
    - air temperature from +10°C  to  +35°C;
    - relative air humidity up to 75%  at  +30°C;
    - air pressure from  84 to 106,7 kPa  (630 - 800 mm Hg).
  2. The GDV Compact operates either from an external power source 12±1 V DC, or from battery (option).
  3. Maximal power consumption - no more than 20 W.
  4. Weight with accessories - no more than 4,5 kg.
  5. Overall dimensions - no more than   250x200x130 mm.
  6. Pulse repetition frequency 1000±100 Hz.
  7. Single pulse duration - no more than 10 µs.
  8. USB-port control of the operation and image transmission to the computer.
  9. Operation during 8 hours in an off and on operating mode: 30 min of operation should be followed by a 10 min break.
  10. Average lifetime - no less than 4 years.
| Top |

GDV Camera"GDV Express "GDV Camera

GDV Express
  1. Operating conditions:
    - air temperature from +10°C  to  +35°C;
    - relative air humidity up to 75%  at  +30°C;
    - air pressure from  84  to  106,7 kPa  (630 - 800 mm Hg).
  2. Operation from an external power source 12±1 V DC. 
  3. Maximal power consumption - no more than 50 W.
  4. Weight with accessories - no more than 10 kg.
  5. Overall dimensions - no more than 470x266x130 mm.
  6. Pulse repetition frequency 1000±100 Hz.
  7. Single pulse duration - no more than 10 µs.
  8. USB-port control of the operation and image transmission to the computer.
  9. Operation during 8 hours in an off and on operating mode: 30 min of operation should be followed by a 20 min break.
  10. Average lifetime - no less than 4 years.
| Top |

GDV+"GDV+"GDV+

GDV+
  1. Operating conditions:
    - air temperature from +10°C  to  +35°C;
    - relative air humidity up to 75%  at  +30°C;
    - air pressure from  84  to  106,7 kPa  (630 - 800 mm Hg).
  2. Weight with accessories - no more than 1,5 kg.
  3. Overall dimensions - no more than 210x140x98 mm.
  4. Pulse repetition frequency 1000±100 Hz.
  5. Automatic exposure - 0,5 s; 1,0 s; 2 - 32 s.
  6. Start of active mode - no less than 20 min after switching it on.
  7. Average lifetime - no less than  4 years.
| Top |

GDV Fifth Element"GDV Fifth Element"GDV Fifth Element

GDV Fifth Element
  1. Operating conditions:
    - air temperature from +10°C  to  +30°C;
    - relative air humidity up to 75%  at  +30°C;
    - air pressure from 84  to  106,7 kPa  (630 - 800 mm Hg).
  2. Weight - no more than 2,5 kg.
  3. Overall dimensions - no more than 135x273x146 mm.
  4. Operation from an internal power source (battery) 12±1 V DC.
  5. Maximal power consumption - no more than 10 W.
  6. Number of input channels - 5.
  7. Average lifetime - no more than 4 years.
| Top |

GDV Fifth Element"GDV Travel"GDV Fifth Element

GDV Fifth Element
  1. Overall dimensions: not more than
    – length 123 mm
    – width 114 mm
    – height 115 mm
  2. Mass of the analyzer: not more than 0.5 kg.
  3. The maximum power consumption is not more than 15 W.
  4. Power supply, mode control and image transmission to the PC is via the USB port. 
  5. Time of going into operating mode: not more than 2 min. The analyzer ensures a 8-hour operation of intermittent cycle: 30-minute operation and 10-minute break, maintaining technical characteristics. 
  6. The analyzer must be capable to work with power supply from the USB port of PC.    
  7. Mean time between failures: not more than 4000 hours.
  8. Lifetime: not more than 4 years.
| Top |