+7 (812) 380-20-02   +7 (911) 132-78-31   gdv.kti@gmail.com

Back to descriptions of GDV devices

Technical Characteristics of GDV devices:

GDV Camera"GDV Camera"GDV Camera

GDV Camera
  1. Operating conditions:
    - air temperature from +10°C  to  +35°C;
    - relative air humidity up to 75%  at  +30°C;
    - air pressure from  84  to  106,7 kPa  (630 - 800 mm Hg).
  2. Operation - from an external power supply 12±1 V DC.
  3. Maximal power consumption - no more than  35 W.
  4. Weight with accessories - no more than 5 kg.
  5. Overall dimensions - no more than  210x390x120 mm.
  6. Pulse repetition frequency   1000±100 Hz.
  7. Single pulse duration - no more than 10 µs.
  8. Automatic exposure - 0,5 s; 1,0 s; 2 - 32 s.
  9. USB-port control of the operation and image transmission to the computer.
  10. Operation during 8 hours in an off and on operating mode: 30 min of operation should be followed by a 5 min break.
  11. Average lifetime - no less than 4 years.
| Top |

GDV Compact"GDV Compact Eco"GDV Compact

GDV Compact

1. Amplitude of generated high-voltage pulses: not more than 5 kV.
2. Pulse repetition rate 1024 Hz.
3. Single pulse duration: not more than 10 μs.
4. Operating conditions:
  – Air temperature from +10°C to +35°C;
  – Relative air humidity 75% at +30°C; 
  – Air pressure from 84 to 106.7 kPa (630–800 mm Hg).
5. The analyzer works from an external DC power supply 12±1V.
6. Maximum power consumption: not more than 20 V.
7. Mass in full package: not more than 4.5 kg.
8. Overall dimensions: not more than 250x200x130 mm.
9. The analyzer is controlled from the computer via serial USB port of from the keyboard on the face surface of the device in off-line mode.
10. Image transmission to the computer is performed via serial USB port or recorded to the USB flash drive.
11. Flash drive memory: not more than 8 Gb.
12. Average lifetime: not more than 4 years.

| Top |

GDV Compact"GDV Compact"GDV Compact

GDV Compact
  1. Operating conditions:
    - air temperature from +10°C  to  +35°C;
    - relative air humidity up to 75%  at  +30°C;
    - air pressure from  84 to 106,7 kPa  (630 - 800 mm Hg).
  2. The GDV Compact operates either from an external power source 12±1 V DC, or from battery (option).
  3. Maximal power consumption - no more than 20 W.
  4. Weight with accessories - no more than 4,5 kg.
  5. Overall dimensions - no more than   250x200x130 mm.
  6. Pulse repetition frequency 1000±100 Hz.
  7. Single pulse duration - no more than 10 µs.
  8. USB-port control of the operation and image transmission to the computer.
  9. Operation during 8 hours in an off and on operating mode: 30 min of operation should be followed by a 10 min break.
  10. Average lifetime - no less than 4 years.
| Top |

GDV Camera"GDV Express "GDV Camera

GDV Express
  1. Operating conditions:
    - air temperature from +10°C  to  +35°C;
    - relative air humidity up to 75%  at  +30°C;
    - air pressure from  84  to  106,7 kPa  (630 - 800 mm Hg).
  2. Operation from an external power source 12±1 V DC. 
  3. Maximal power consumption - no more than 50 W.
  4. Weight with accessories - no more than 10 kg.
  5. Overall dimensions - no more than 470x266x130 mm.
  6. Pulse repetition frequency 1000±100 Hz.
  7. Single pulse duration - no more than 10 µs.
  8. USB-port control of the operation and image transmission to the computer.
  9. Operation during 8 hours in an off and on operating mode: 30 min of operation should be followed by a 20 min break.
  10. Average lifetime - no less than 4 years.
| Top |

GDV Light"GDV Light"GDV Light

GDV Light
  1. Operating conditions:
    - air temperature from +10°C  to  +35°C;
    - relative air humidity up to 80%  at  +25°C;
    - air pressure from  84  to  106,7 kPa  (630 - 800 mm Hg).
  2. Weight with accessories - no more than 2,5 kg.
  3. Overall dimensions - no more than 250x200x130 mm.
  4. Analyzer is operated only in complex with the computer.
| Top |

GDV+"GDV+"GDV+

GDV+
  1. Operating conditions:
    - air temperature from +10°C  to  +35°C;
    - relative air humidity up to 75%  at  +30°C;
    - air pressure from  84  to  106,7 kPa  (630 - 800 mm Hg).
  2. Weight with accessories - no more than 1,5 kg.
  3. Overall dimensions - no more than 210x140x98 mm.
  4. Pulse repetition frequency 1000±100 Hz.
  5. Automatic exposure - 0,5 s; 1,0 s; 2 - 32 s.
  6. Start of active mode - no less than 20 min after switching it on.
  7. Average lifetime - no less than  4 years.
| Top |

GDV Fifth Element"GDV Fifth Element"GDV Fifth Element

GDV Fifth Element
  1. Operating conditions:
    - air temperature from +10°C  to  +30°C;
    - relative air humidity up to 75%  at  +30°C;
    - air pressure from 84  to  106,7 kPa  (630 - 800 mm Hg).
  2. Weight - no more than 2,5 kg.
  3. Overall dimensions - no more than 135x273x146 mm.
  4. Operation from an internal power source (battery) 12±1 V DC.
  5. Maximal power consumption - no more than 10 W.
  6. Number of input channels - 5.
  7. Average lifetime - no more than 4 years.
| Top |